U·CUniversal ConcreteFloor quantities & site levels
Menu

Concrete field journal

Sources and document dates

Technical references, not product recommendations. Arithmetic methods and manufacturer conditions are kept separate.

How to use these references

References support the explanations beside the calculations. They do not approve the inputs or the job. Follow the current project specification and exact manufacturer document; the access date below is when the linked document was checked, not a guarantee that it will remain unchanged.

The two tools use the arithmetic described on methodology. Product consumption, bag mass, thickness regimes, drawing gradients and tolerances remain values you supply. Manufacturer references here illustrate why those conditions need checking; they are not recommendations or automatic presets.

Source pages sometimes include general time ranges, historical standards or product-specific thresholds. Those are not universal curing, loading, finishing or moisture limits. Where a source mentions a standard, that standard itself has not been reviewed here.

Construction hazardous substances: Cement

Health and Safety Executive. Undated web guidance. Accessed 2026-10-12.

Wet cement can cause burns and dermatitis; waterproof protection, contact reduction and prompt washing are controls.

Safety guidance, not a product constant or calculator approval.

Read the publisher’s document

Curing concrete

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Curing prevents moisture loss while maintaining a suitable temperature regime; required duration depends on cement and ambient conditions.

The source generalises a curing duration; no fixed period is copied into these guides or tools.

Read the publisher’s document

Concrete type by property

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Concrete type names may reflect final application or material properties.

Definitions, not selection or structural recommendations.

Read the publisher’s document

Finish of concrete

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Formed appearance depends on formwork and mix; unformed appearance depends on finishing.

No finish certification or slip-performance claim.

Read the publisher’s document

Surface finish specification

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Finish descriptions need agreed requirements and physical benchmarks; vague descriptions are inadequate.

Background on specifying finishes; not a finish specification for any job.

Read the publisher’s document

Using 56 day concrete strengths

The Concrete Centre (MPA). 7 June 2021; Concrete Magazine, June 2021. Accessed 2026-10-12.

Strength gain depends on cement and curing conditions; drying out can stop further hydration.

Historical technical discussion only, not current structural design or safe-loading instructions.

Read the publisher’s document

ARDEX K 15 Product Data Sheet

ARDEX UK Limited. September 2025; supersedes January 2024. Accessed 2026-10-12.

Coverage approximately 1.4 kg/m²/mm; 22 kg net bag; thickness and substrate regimes are separately qualified in the document.

Document illustration only. No product preset or recommendation. Headline 1.5–35 mm is not one unconditional application regime.

Read the publisher’s document

Constituents of concrete

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Basic constituents are cement, water and aggregate; other constituents modify fresh or hardened properties.

No mix recipe.

Read the publisher’s document

Bleeding and segregation

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Water can rise to the surface; remixing bleed water during finishing leaves a weak top; rapid evaporation can create a plastic-shrinkage risk.

No finishing start timer, crack probability or safe-weather threshold.

Read the publisher’s document

Excess or added water to concrete

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Excess water beyond permitted tolerance changes designed water/cement ratio and can impair strength, durability and finish.

The source numerical strength example is not used as a prediction.

Read the publisher’s document

Self compacting concrete

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Self-compacting concrete flows under its own weight without mechanical vibration; its fresh properties differ from conventional concrete.

Page contains historical standards references and a probable standard-number typo; none are reproduced as current authoritative standards.

Read the publisher’s document

Concrete from ready-mixed concrete suppliers

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Ready-mixed plants batch by weight; designated, designed, prescribed, standardised prescribed and proprietary are specification categories.

No recipe or grade allocation.

Read the publisher’s document

Cement and additions

The Concrete Society. Web guidance; no numbered edition shown. Accessed 2026-10-12.

Cement hardens by chemical reaction with water; hydration needs water; curing retains it.

No hydration-to-strength model or date guarantee.

Read the publisher’s document

Digital Hygrometer Technical Data Sheet

F. Ball and Co. Ltd. April 2024; QCP 4737. Accessed 2026-10-12.

A moisture test precedes bonding floorcoverings; the hygrometer measures confined air in equilibrium with the subfloor, isolated from surrounding air. Artificial drying and heating need conditioning before testing.

System-specific test method. Numeric RH thresholds, test durations and moisture-product recommendations are not universal tool defaults.

Read the publisher’s document

These references cover concrete curing, concrete surface finish and wet cement exposure. They explain the site cautions in the guides; they do not approve a product, a drawing or a project specification.